The Milwaukee MW101 soil PH meter is a reliable, fast, easy-to-operate and high-precision rugged meter. The Milwaukee PRO pH Meter is preferred by those who test samples that cause other pH testers and meters to fail, from brewers and winemakers to hydroponic producers and farmers.
MW101 general purpose portable pH meter with 0.01 pH resolution
Simple but extremely intelligent portable measuring instrument. A low-cost, durable measuring instrument that provides fast and reliable measurement.
Due to its design, it can be an easy-to-use, practical and precise tool for workshops. Ideal for lessons, laboratories or general on-site use. The Milwaukee MW101 performs pH measurements with 0.01 pH resolution and manual temperature compensation.
DESIGN CHARACTERISTICS
- Fast, easy-to-read results with large digital LCD readings.
- Exactly ± 0.02 pH in the pH range 0.00-14.00.
- Lightweight and portable.
- Easy measurement: just place the sample in the sample, mix gently and wait for the reading to stabilize
- Easy manual two-point calibration for greater accuracy.
- Gel-filled, double-branched laboratory pH electrode for low maintenance and high performance with screw cap for proper storage (including SE220 probe).
- 3-pin probe cables for extra flexibility during testing.
- Automatic switch-off and low power consumption approx. 300 hours of continuous use. (including battery)
STORAGE
The pH probe must be kept hydrated. Prolonged dry storage may damage the sensitivity of the probe. If the probe is allowed to dry, the bifurcation hole may become clogged. Storage in the pH measuring probe storage solution MA9015 or in the pH calibration buffers helps to address both problems. Do not store in tap water and DI water. This will damage the sensitivity of the probe. The best way to store the probe is to fill the probe cap with storage solution or calibration buffer and tighten the cap to prevent leakage. We also recommend that you store the electrode vertically to further reduce the possibility of leakage.
CLEANING
Residues from the sample can affect the sensitivity of the sensor bulb and clog the node. This is especially true if there is a lot of organic matter in the sample. It is recommended that the electrode be soaked regularly in MA9016 cleaning solution.
CALIBRATION
PH sensor bulbs are less sensitive over time, so be sure to calibrate regularly to ensure that your PRO pH meter is accurate. Also calibrate after cleaning or prolonged storage.
Sve informacije koje se nalaze ovde su informacije od strane proizvođača.
Proizvođač zadržava pravo na izmene ili promene informacija bez predhodne najave i bez ikakve odgovornosti.
Za promene, odstupanja ne možemo da prihvatimo odgovornost.
Slika koja prikazuje određeni proizvod je ilustracija, u stvarnosti proizvod može da odstupa od ilustrovane slike.
Milwaukee MW101 soil PH meter komentari
Uopšte nema komentara za proizvode.